Find the construction solution for your project here.
Please note that the solutions presented are designed for Norwegian building regulations and rules.
We provide you with construction solutions tailored to your fire and sound requirements.
It’s of course about building technical requirements for safety, but also about comfort in terms of air and sound.
Showing 12 of 49 matches.
-
Wall – Outer wall – Fig num. 77
15mm brannplaster – 13mm plaster – 30x48mm batten – Masonite R200 – cellulose blow-in insulation – 9mm exwoodennal plaster – 22x48mm batten – 19x148mm exwoodennal cladding
-
Wall – Outer wall – Fig num. 75
13mm plaster – Masonite H200 – 200mm Mineral wool – woodenbasert exwoodennal plate 7mm
-
Wall – Outer wall – Fig num. 78
13mm plaster – 30x48mm batten – Masonite R200 – cellulose blow-in insulation – 9mm exwoodennal plaster – 22x48mm batten – 19x148mm exwoodennal cladding
-
Wall – Outer wall – Fig num. 79
15mm brannplaster – 13mm plaster – 30x48mm batten – Masonite R200 – 200mm Glass wool – 9mm exwoodennal plaster – 22x48mm batten – 19x148mm exwoodennal cladding
-
Wall – Outer wall – Fig num. 80
Wood-based board Huntonit Brannit – 15mm brannplaster – 30x48mm batten – Masonite R200 – 200mm Glass wool – 9mm exwoodennal plaster
-
Wall – Inner wall – Fig num. 63
Wood-based board – 70mm Mineral wool – 100mm steelstud – 13mm plaster – Wood-based board
-
Wall – Inner wall – Fig num. 64
Wood-based board – 13mm plaster – 70mm Mineral wool – 100mm steelstud – 13mm plaster x2 – Wood-based board
-
Wall – Inner wall – Fig num. 67
Wood-based board – 75mm steelstud – 100mm Glass wool – Wood-based board
-
Wall – Inner wall – Fig num. 68
Wood-based board x2 – 75mm steelstud – 100mm Glass wool – Wood-based board x2
-
Wall – Outer wall – Fig num. 73
Wood-based board – Masonite R200 – 200mm Mineral wool – woodenbasert exwoodennal plate
-
Wall – Outer wall – Fig num. 72
13mm plaster – 48x48mm batten – 48mm Mineral wool – Masonite R200 – 200mm Glass wool – 9mm exwoodennal plaster